Endoreversible thermodynamics

Endoreversible thermodynamics is a subset of irreversible thermodynamics aimed at making more realistic assumptions about heat transfer than are typically made in reversible thermodynamics.

It gives an upper bound on the power that can be derived from a real process that is lower than that predicted by Carnot for a Carnot cycle, and accommodates the exergy destruction occurring as heat is transferred irreversibly.

It is also called finite-time thermodynamics, entropy generation minimization, or thermodynamic optimization.

[1] Endoreversible thermodynamics was discovered multiple times, with Reitlinger (1929),[2] Novikov (1957)[3][4] and Chambadal (1957),[5] although it is most often attributed to Curzon & Ahlborn (1975).

[6] Reitlinger derived it by considering a heat exchanger receiving heat from a finite hot stream fed by a combustion process.

A brief review of the history of rediscoveries is in.

, but other operations happen instantly.

Its maximal efficiency is the standard Carnot result, but it requires heat transfer to be reversible (quasistatic), thus taking infinite time.

At maximum power output, its efficiency is the Chambadal–Novikov efficiency: Due to occasional confusion about the origins of the above equation, it is sometimes named the Chambadal–Novikov–Curzon–Ahlborn efficiency.

This derivation is a slight simplification of Curzon & Ahlborn.

On one side, the working fluid has temperature

, and is in direct contact with the hot heat bath.

, and is in direct contact with the cold heat bath.

Side note: if one cycle of the engine takes time

, then we can reduce to this case by replacing

Similar comments apply to the cold side.

This then gives us a problem of constraint optimization:

This can be solved by typical methods, such as Lagrange multipliers, giving us

at which point the engine is operating at efficiency

This is often the case with practical heat engines in power generation plants, where the work fluid can only spend a small amount of time with the hot bath (nuclear reactor core, coal furnance, etc), but a much larger amount of time with the cold bath (open atmosphere, a large body of water, etc).

For some typical cycles, the above equation (note that absolute temperatures must be used) gives the following results:[6][9] As shown, the endoreversible efficiency much more closely models the observed data.

However, such an engine violates Carnot's principle which states that work can be done any time there is a difference in temperature.

The fact that the hot and cold reservoirs are not at the same temperature as the working fluid they are in contact with means that work can and is done at the hot and cold reservoirs.

The result is tantamount to coupling the high and low temperature parts of the cycle, so that the cycle collapses.

[10] In the Carnot cycle, the working fluid must always remain constant temperatures, as the heat reservoirs they are in contact with and that they are separated by adiabatic transformations which prevent thermal contact.

The efficiency was first derived by William Thomson[11] in his study of an unevenly heated body in which the adiabatic partitions between bodies at different temperatures are removed and maximum work is performed.

An introduction to endoreversible thermodynamics is given in the thesis by Katharina Wagner.

[8] It is also introduced by Hoffman et al.[12][13] A thorough discussion of the concept, together with many applications in engineering, is given in the book by Hans Ulrich Fuchs.

Novikov engine showing irreversible heat transfer between and , coupled to a Carnot cycle operating between and . [ 8 ]
The plot of Chambadal–Novikov efficiency as a function of Carnot efficiency. We see that it is always less than Carnot efficiency, but approaches it at the two ends.